290-01 Siemens S7 1200 Connections

Connecting the Siemens PLC to the trainer:
Upper Terminal Strip - PLC Inputs and Power Connections
| Trainer | Siemens PLC | Description | 
| +24V | 24V DC L+ | 24 V DC input power source | 
| +12V | Not connected | |
| 0V | 24V DC M | 0 V DC input power source | 
| R1 | DIa 0 | Cylinder reed switch 1 active | 
| R2 | DIa 1 | Cylinder reed switch 2 active | 
| R3 | DIa 2 | Cylinder reed switch 3 active | 
| S1 | DIa 3 | Optical beam sensor 1 not broken | 
| S2 | DIa 4 | Optical beam sensor 2 not broken | 
| SWR | DIa 5 | Red button pressed | 
| SWG | DIa 6 | Green button pressed | 
| +24V | Not connected | |
| 0V | DIa 1M | Digital 0 V reference | 
| VR | AI 0 | Analogue dial control (0-27648) | 
| 0V | AI 2M | Analogue 0 V reference | 

Lower Terminal Strip - PLC Outputs and Power Connections
| Trainer | Siemens PLC | Description | 
| 24V | 3L+ | 24 V source for outputs | 
| 12V | Not connected | |
| 0V | 3M | 0 V reference for outputs | 
| C1 | DQa 0 | Activate cylinder 1 | 
| C2 | DQa 1 | Activate cylinder 2 | 
| C3 | DQa 2 | Activate cylinder 3 | 
| E | DQa 3 | Enable conveyor | 
| R | DQa 4 | Reverse conveyor | 
| LR | DQa 5 | Illuminate red lamp | 
| LG | DQa 6 | Illuminate green lamp | 
| 24V | Not connected | |
| 0V | Not connected | |
| M | AQ 0 | Analogue motor speed control (0-27648) | 
| 0V | AQ 0M | Analogue 0 V reference | 

The supplied wire set has terminal connections on each end and different coloured wires to make the wiring easier.
Use a flat bladed screwdriver and ensure that power is switched off when connecting/disconnecting the unit.